Search

Search results

  1. Un-Routed Net

    ... Summary This rule tests the completion status of each net that falls under the scope (full query) of the rule. If a net is incomplete ... DRC. Notes Some split plane DRC checks require the Un-Routed Net rule to be Batch-enabled for them to work.   ...

    admin - 11/06/2013 - 09:54

  2. Un-Routed Net

    ... Summary This rule tests the completion status of each net that falls under the scope (full query) of the rule. If a net is incomplete ... DRC. Notes Some split plane DRC checks require the Un-Routed Net rule to be Batch-enabled for them to work.   ...

    admin - 09/13/2017 - 15:32

  3. Design Rule Checker

    ... length and width errors on the PCB document. Sub-Net Details -  If you have an  Un-Routed Net  rule defined, enable this option to include  Sub-Net Details ...

    admin - 11/06/2013 - 09:54

  4. Electrical ルール

    ... Short Circuit Unconnected Pin Unrouted Net ...

    admin - 08/23/2019 - 14:29

  5. Design Rule Checker

    ... length and width errors on the PCB document. Sub-Net Details -  If you have an  Un-Routed Net  rule defined, enable this option to include  Sub-Net Details ...

    admin - 09/13/2017 - 15:32

  6. Tracking Down Broken Nets

    When a net is not completely routed, it is reported as a violation of the applicable Unrouted Net rule. The net is considered to be broken. The violation details ... sub-nets indicates two breaks, etc.A break, or rather an unrouted connection, can be quickly found using the PCB panel. You could of ...

    admin - 11/06/2013 - 05:11

  7. Tracking Down Broken Nets

    When a net is not completely routed, it is reported as a violation of the applicable Unrouted Net rule. The net is considered to be broken. The violation details ... sub-nets indicates two breaks, etc.A break, or rather an unrouted connection, can be quickly found using the PCB panel. You could of ...

    admin - 09/13/2017 - 15:32

  8. Violation

    ... line is broken by a double-slash. This indicates that the net is un-routed (broken) between the via and pad. Use the detail markers to help ...

    admin - 11/21/2013 - 09:34

  9. Run SI

    ... yet been transferred to the PCB. The latter will be used for unrouted nets that have been transferred to the PCB, in addition to defined ... appear, listing the results of this initial analysis. Each net will be given one of three possible status settings: Passed (green ...

    admin - 11/06/2013 - 09:54

  10. Un Route Net

    ... PCB:UnRoute Applied parameters:   Object = Net Summary This command enables you to unroute all physical connections for a specific net. Availability In PCB Editor, run command  Tools » Un-Route ... select No , then only track that is not locked will be unrouted.     ...

    admin - 11/06/2013 - 09:54

Pages

You are reporting an issue with the following selected text and/or image within the active document: